Table of Contents

IR Blaster CFLink Protocol

The following documentation is for the IR Blaster device CFLink protocol messages.

Transmission Messages

SND - Send IR

The SND (Send) command is used to send an IR command via one or more IR ports on the IR Blaster.

Data

> [F2]<ID>[F3]TIRBSND[F4]<PORT>:<IR_FORMAT>:<IR_DATA>[F5][F5]

Note that a single SND command can contain multiple ports to send to, using the standard port separators

Reply

// The reply does not echo the data sent in an effort to reduce bus traffic
< [F2]<ID>[F3]RIRBSND[F4][F5][F5]
If sending multiple IR commands via a single CFLink message, the reply will only happen after all IR commands have been sent.

Example

// Send a CCF hex code via the Blaster output. Send a database IR code to the secondary emitter output.  
// From IR Blaster on CFLink ID [06].
> [F2][06][F3]TIRBSND[F4]P01:RAW:0000 0067 0000 0015 0060 0018 0030 0018 0018 0018 0030 0018 0018 0018 0030 0018 0018 0018 0018 0018 0018 0018 0030 0018 0018 0018 0030 0018 0030 0018 0030 0018 0018 0018 0018 0018 0030 0018 0018 0018 0018 0018 0030 0018 0018 0216|P02:DBA:06:1033:01[F5][F5]
// Reply
< [F2][06][F3]RIRBSND[F4][F5][F5]

Error

Notifications

RCV - Receive IR Data

The RCV (Receive) notification is generated when either the on-board IR receiver, or the external IR receiver detects an IR signal.

Data

< [F2]<ID>[F3]RIRBRCV[F4]<PORT>:<IR_DATA>[F5][F5]

Example

// IR Data is received via the on-board IR receiver, IR Blaster on CFLink ID [06]
< [F2][06][F3]RIRBRCV[F4]P01:0066016100160119001601320016011A0016011900160132001601310016011A0016[F5][F5]